Basic Info.
Connection Mode
Series Switching Power Supply
Specification
230*132*52 mm
Product Description
Dual Output hv power supply HVLP-EV-100A 150W Air Purifier:Product Description:
Application occasions : High voltage electric field, Electrotatic air cleaner ,Industrial dirty gas purification, air purifiers ,air ionizer,clean smoke,etc
Model: HVLP-EV-100A
Input voltage: 180V~250V
Output voltage: low voltage:DC 4KV~8KV high voltage:DC 8KV~15KV
*(Custom service is available)
Output current:0~10mA
Max output power:150W
size:230mm*132mm*52mm
Usage instruction:
1. Connect the high-voltage output line to the required load (high-voltage electric field), the H interface is the high-voltage positive pole, and the L interface is the low-voltage positive pole,the power supply shell is the common high voltage negative pole. The H interface is connected to the ionizing electric field (with sawtooth plate or molybdenum wire),The L interface is connected to the positive plate of the adsorption electric field (the electric fieldwith the plate closer).The power supply shell and the chassis shell ensure good contact.
Please note that a power supply can only drive 1-2 sets of conventional electric fields, not more than 2 sets of electric fields, otherwise the power supply will work abnormally due to excessive load.
2. According to the interface shown in Figure 1,connect the green interface 1 and 2 to 220V AC voltage.((Note: interface 1 and 2 are 220V input interface, and there is no distinction between neutral and live wires. Interface 3 is a ground wire. Users should connect them according to the actual situation, and there is no mandatory requirement.)At this time, the working indicator (green) is on, and the high-voltage power supply starts to output high-voltage.
Adjust the voltage adjustment potentiometer to select the desired voltage; adjust the output voltage clockwise to increase, and counterclockwise to decrease the voltage
3. When there is a slight ignition inside the electric field, the red alarm indicator light is on, and the work indicator light is always on.If the spark disappears, the red light is off, the power supply will not turn off the high voltage output.
When there is continuous arcing or short circuit inside the electric field, the red alarm indicator lights up.At the same time, the workingindicator is off, the power is turned off, and the power is restarted after a delay of 1-2 seconds.
If there is a short circuit inside the electric field, the high-voltage line is open, or the inside of the electric field is too dirty, the yellow indicator light will be on. At this time, please focus on checking the electric field, insulators and the wiring of the high-voltage line.
4. Interface 4-6 are external indicator light interface. The working voltage of the indicator light is 12V and the working current is less than 20mA.
Precautions:- The high voltage output line must be away from the 220V input line, and the two cannot be bundled together or close to the cable.
- The output voltage should not be adjusted to the position of the maximum output voltage for a long time, Need to reserve a certain amount of margin, generally reserve a margin of about 10% to 30%.
- Two high-voltage output lines cannot be tied together and arranged together, otherwise they will burn out easily.
- Where the high-voltage line is perforated in the chassis, a wall-through porcelain tube or an insulating tube is required.
- The high voltage power supply should be kept away from the hot and humid environment, installation of cooling fans in distribution boxes, pay attention to ventilation.
NOTICE
1. Read the instructions carefully before installing the power supply, and the technicians with relevant electrical installation certificates should be invited to carry out the installation.
2. The power supply should be installed in a case that is more than 2.5 times larger than the power supply, the case should be able to ventilate and waterproof, avoid direct sunlight in the summer, if the ambient temperature is too high, consider installing a fan to dissipate heat.
3. The high voltage output should be connected to the load and sealed in a metal case with a solid ground wire that can be powered on, to avoid the risk of high pressure clicks. Pay attention to the identification of the power supply when connecting the high voltage line: Red line (high voltage negative electrode), black line (high voltage positive electrode). The grounding end of the electric field should be firmly connected to the ground together with the case, grounding resistance is not more than 2Ω.
4.The high voltage output line of the high voltage power supply needs to be isolated from the 220V input line and other control lines, can not be tied together for wiring. High voltage trace and other traces require tight control of spacing(Spacing >=15cm), and the high voltage output positive and negative lines also need a distance of at least 10cm, avoid discharge breakdown between the positive and negative high voltage lines.
5. The input of the power supply should be installed with fuse, air switch, then connect to the 220VAC power supply.
6. Purifier under the action of high voltage electrostatic field, when the pollutant adsorbed by the electrode reaches a certain amount, manual or automated mechanical cleaning of the purifier is required. If not clean in time, a large amount of pollutants adsorbed cause sparking or corona on the electrode. This corona phenomenon will reduce the efficiency of the purifier device, flashover sparks are also prone to fire when flammable substances are present, and this flashover arc will also pollute the grid. If you found ignition protection light on during the use of high voltage power supply, please pay attention to checking and cleaning the electrode in time.
7. The high-voltage line needs to use a wall-through porcelain tube or an insulating tube in the place where the case is perforated. Don't pass the high voltage wire directly through the opening of the case, otherwise it is easy for the high-voltage wire to pull or even burn the high-voltage wire at the perforation. The main control board of this power supply has 220V high voltage, Do not touch bare metal parts of the board during adjustment, in order to avoid electric shock.
Contact Us
ADD:No.757 Laser Industrial Park,High-tech center, Anshan, Liaoning, .China
TEL:+86-412-2660889 2666636 5237711
FAX:+86-412-2663889 5237722
ANSHAN LEADSUN ELECTRONICS CO., LTD.
Address:
No. 8 Guangshu Road, Lishan District, Anshan, Liaoning, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001
Company Introduction:
This is leadsun electronics from Anshan, China. Our company is specializing in designing and producing types of high voltage components, such as high voltage diodes, high voltage bridge rectifier, high voltage silicon assembly, special high voltage modular, multiply voltage modular and high frequency high voltage power supply. These products are widely applied for electrostatic cleaning, medical X-ray machine, CT, MR, dehydrating of crude oil, broadcast launching, laser power supply, high voltage modular, high voltage test equipment, TV/display FBT, air purifier, power supply, etc.