Resistance range | 1*107~1*1012(Ω) |
Resistance error | G(±2%) J(±5%) K(±10%) |
Operating temperature | -55ºC~+80ºC |
Temperature Coefficient | +20ºC~+85ºC±500*10-6/ºC;+20ºC~-55ºC±500*10-6/ºC |
Steady state damp heat | △R≤±(5%R+0.1W) |
Operating Voltage | 1000V |
Testing item | Test condition and Performance index request | Testing result |
Overload |
100W:1.7MΩ-29.10KV;2.1MΩ-32.40KV; 3.3MΩ-40.62KV; 5.5MΩ-52.40KV; 150W: 6.6MΩ-70.36KV: ΔR ≤(±1%)R |
100W: ΔR(0-0.49)%R 150W: ΔR(0.15-0.20)%R Qualified |
Short time overload |
Test condition:Four time working voltage, Duration time:1min /60S 100W resistor:1.7MΩ-13.20KV;2.1MΩ-16.64KV; 3.3MΩ-26.40KV; 5.5MΩ-44.00KV; 150W resistor: 6.6MΩ 52.80KV |
No burning phenomenon occurred in the resistor,and no breakdown, arcing, carbonization occurred on the surface of the insulating layer. Qualified |
Insulation resistance | Test condition:DC500V,Duration time=60s Foli wrapping method:AC 700V, Duration time=60s Index requirements: Insulation resistance RI≥10GΩ |
RI:(40~200)GΩ Foli wrapping method:RI:∞ Ω Qualified |
Temperature coefficient | Test condition:-15ºC~+25ºC +25ºC~+125ºC Index requirements TCR ≤ ±400PPM/ºC |
(-15ºC~+25ºC) -(48.9~396.5)PPM/ºC (+25ºC~125ºC) (5.7~377)PPM/ºC Qualified |
Steadydamp-heat | Test condition T:(40±2.0)ºC,RH:(90~95)% t:96h Index requirements:ΔR ≤ (±2%)R |
ΔR: (0.00-0.38)%R Qualified |
Vibration | Test condition:10Hz--500Hz,A=0.75mm or a=98m/s²,Duration time 6h. 10min cycle once for a total of 36 times. Index requirements: ΔR ≤(±2%)R |
ΔR: (-0.06--0.12)R Qualified |
Temperature fast changed | Test condition:resistor at the (-55±3)ºCof the condition duration 30min, temp rising timely (125±3)ºC,duration 30min,total of 5 cycles Index requirements:ΔR ≤(±1%)R |
ΔR: (-0.10~0.06)%R Qualified |
70ºC durability | Test condition:The resistor applies a rated power voltage and remains in the (70±2)ºC environment for 96h. Index requirements: ΔR ≤(±1%)R |
ΔR: (0~0.62)%R Qualified |