Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Description:
Application occasions : High voltage electric field, Electrotatic air cleaner ,Industrial dirty gas purification, air purifiers ,air ionizer,clean smoke,etc
Model: HVLP-EV-1000A
Input voltage: 180~250V(AC 50-60Hz)
Output voltage: 2KV~20KV(continuously)
*(Custom service is available)
Output current:0~50mA
Max output power:1000W
weight: 9kg
size:375mm*240mm*130mm
Operation steps:
Description of operating mode
There are "start", "stop" and "adjustment" buttons inside the power supply to switch between three working modes.
Operating mode: When the "Start" button is pressed, the power supply enters the working mode. In the working mode, the high-voltage power indicatorlashes periodically at intervals of 1S, which indicates that the high-voltage power supply starts to work. After the startup waits for 1.5S, the cooling fan starts to work, and the high voltage starts to output.
Stop mode: When the "program" button is pressed, the power enters the stop mode. In the stop mode, the high voltage power supply cuts off the high voltage output, the work indicator and the alarm indicator are off, and the cooling fan stops running.
Adjustment mode: When the "adjustment" button is pressed, the power supply enters the adjustment mode. The adjustment mode is specifically for the device to adjust the output voltage during installation to adapt to different electric fields. In order to cooperate with the installer's work, we have added this mode. Due to the adjustment mode, the ignition protection of the high-voltage power supply is turned off, (other protections are working normally). Adjust the potentiometer at this time, adjust the appropriate voltage, and then press the start button to make the power supply work.
Cleaning mode: When the power running time reaches 720 hours (one month), the yellow cleaning indicator will flash to remind the user to clean the electric field. After the user presses the cleaning button, the cleaning indicator will go out, the accumulated time will be cleared, and the cleaning indicator will not affect the normal work, only for notice.
Protection function
NOTICE
1. Read the instructions carefully before installing the power supply, and the technicians with relevant electrical installation certificates should be invited to carry out the installation.
2. The power supply should be installed in a case that is more than 2.5 times larger than the power supply, the case should be able to ventilate and waterproof, avoid direct sunlight in the summer, if the ambient temperature is too high, consider installing a fan to dissipate heat.
3. The high voltage output should be connected to the load and sealed in a metal case with a solid ground wire that can be powered on, to avoid the risk of high pressure clicks. Pay attention to the identification of the power supply when connecting the high voltage line: Red line (high voltage negative electrode), black line (high voltage positive electrode). The grounding end of the electric field should be firmly connected to the ground together with the case, grounding resistance is not more than 2Ω.
4.The high voltage output line of the high voltage power supply needs to be isolated from the 220V input line and other control lines, can not be tied together for wiring. High voltage trace and other traces require tight control of spacing(Spacing >=15cm), and the high voltage output positive and negative lines also need a distance of at least 10cm, avoid discharge breakdown between the positive and negative high voltage lines.
5. The input of the power supply should be installed with fuse, air switch, then connect to the 220VAC power supply.
6. Purifier under the action of high voltage electrostatic field, when the pollutant adsorbed by the electrode reaches a certain amount, manual or automated mechanical cleaning of the purifier is required. If not clean in time, a large amount of pollutants adsorbed cause sparking or corona on the electrode. This corona phenomenon will reduce the efficiency of the purifier device, flashover sparks are also prone to fire when flammable substances are present, and this flashover arc will also pollute the grid. If you found ignition protection light on during the use of high voltage power supply, please pay attention to checking and cleaning the electrode in time.
7. The high-voltage line needs to use a wall-through porcelain tube or an insulating tube in the place where the case is perforated. Don't pass the high voltage wire directly through the opening of the case, otherwise it is easy for the high-voltage wire to pull or even burn the high-voltage wire at the perforation. The main control board of this power supply has 220V high voltage, Do not touch bare metal parts of the board during adjustment, in order to avoid electric shock.
Contact Us